What is NA2XS2Y 6/10 (12)kV Cable?

The NA2XS2Y 6/10 (12)kV Cable is a single-core aluminium conductor medium-voltage power distribution cable manufactured according to IEC 60502-2 and IEC 60228 standards. It is engineered for 10kV electrical utility networks, primary sub-transmission systems, substation transformer connections, and industrial feeder lines where mechanical durability and environmental resistance are required for underground installation.

The standard German DIN VDE designation outlines each structural component: NA indicates an aluminium conductor manufactured to IEC 60228 Class 2; 2X specifies Cross-Linked Polyethylene (XLPE) dielectric insulation; S represents a concentric metallic screen composed of copper wires and equalizing copper tape; and 2Y denotes a protective Medium Density Polyethylene (MDPE) outer jacket. Designed for standard dry to moderately drained trench routes, NA2XS2Y delivers AG2 impact endurance, EN 60229-4.1 abrasion protection, and ISO 4892-3 UV stability for direct-burial and ducted configurations.

NA2XS2Y 6/10 (12)kV Cable - XLPE MDPE Medium Voltage Power Cable

NA2XS2Y 6/10 (12)kV Cable Construction

  • Conductor: Class 2 stranded compacted circular aluminium conductor conforming to IEC 60228.
  • Conductor Screen: Extruded semi-conductive compound bonded directly over the conductor to eliminate electrical field stress concentrations.
  • Insulation: High-purity Cross-Linked Polyethylene (XLPE) compound with a nominal thickness of 3.40mm (minimum 2.96mm), delivering dielectric strength and thermal endurance up to +90°C.
  • Insulation Screen: Extruded semi-conductive material bonded to the XLPE insulation layer for uniform radial electrostatic field distribution.
  • Metallic Screen: Concentric annealed copper wires overlaid with a helically applied copper tape to safely conduct system fault currents.
  • Outer Sheath: Medium Density Polyethylene (MDPE) compound complying with EN 60229-4.1 for resistance against abrasion, tearing, and environmental cracking.
  • Sheath Colour: Available in Red or Black.
  • Material Performance: UV resistant (ISO 4892-3), abrasion and tear resistant (EN 60229-4.1), impact rated to AG2 (EN 60364-5.51), and halogen-free (IEC 60754).

Applications

NA2XS2Y 6/10 (12)kV cables provide power transmission across outdoor, subterranean, and industrial installations:

  • Public & Private Utility Grids: Primary 10kV distribution circuits connecting municipal substations, switching stations, and step-down transformers.
  • Direct Burial in Ground: Trench routing in standard soil profiles, utilizing the mechanical abrasion and impact protection of the tough MDPE outer sheath.
  • Buried Cable Ducts & Tunnels: Installation inside concrete raceways, underground utility banks, and duct systems withstanding pulling friction.
  • Renewable Energy Collector Networks: Medium-voltage collector circuits routing power from wind turbine bases and solar PV inverter stations to central substations.
  • Industrial Manufacturing Complexes: Main external distribution lines for manufacturing plants, mining operations, and refineries requiring AG2 impact protection and chemical durability.

Specifications & Dimensions

Huadong Cable Group manufactures NA2XS2Y 6/10 (12)kV cables across single-core aluminium cross-sections from 50mm² up to 630mm² (including 50, 70, 95, 120, 150, 185, 240, 300, 400, 500, and 630mm²). Rated for 6/10 (12)kV with a 21kV AC 5-minute dielectric test voltage, the series features nominal overall outer diameters from 23mm (50mm²) up to 46mm (630mm²) and unit weights spanning 550 kg/km to 3,000 kg/km. Nominal XLPE insulation thickness is standardized at 3.40mm, complemented by copper screen cross-sections of 16mm², 25mm², or 35mm² yielding short-circuit screen current capacities from 3.2kA to 7.1kA for 1 second. Permissible continuous current carrying capacity reaches up to 701A in ground (20°C) and 882A in free air (30°C) for 630mm² conductors under flat touching formation. Maximum pulling tension ratings range from 1,500 N up to 18,900 N, and maximum sidewall pressures reach 1,654 N/cm² under an installation bending radius of 15 times the overall diameter, fully conforming to IEC 60502-2 specifications.

No. of CoresNominal Cross Sectional Area - Conductor (mm2)Nominal Cross Sectional Area - Screen (mm2)Nominal Conductor Diameter (mm)Number and Diameter of Conductor WiresSemi-Conductive Layer Thickness, Inner (mm)Semi-Conductive Layer Thickness, Outer (mm)Nominal Insulation Thickness (mm)Minimum Insulation Thickness (mm)Nominal Diameter Over Insulation (mm)Number and Diameter of Screen WiresTape Screen ConstructionNominal Sheath Thickness (mm)Minimum Sheath Thickness (mm)Nominal Overall Diameter (mm)Nominal Weight (kg/km)Maximum Sidewall Pressure (N/cm2)Maximum Pulling Tension (N)
150168.27 x 2.900.50.43.42.9616.444 x 0.661x0.1x101.81.24235503311500
170169.719 x 2.180.50.43.42.9617.944 x 0.661x0.1x101.81.24246504152100
1951611.419 x 2.550.50.43.42.9619.644 x 0.661x0.1x101.81.24267505222850
11201612.6519 x 2.900.50.43.42.9620.944 x 0.661x0.1x101.81.24278506214500
11502514.419 x 3.160.50.43.42.9622.671 x 0.661x0.1x101.91.322911007087500
11852515.7537 x 2.550.50.43.42.9624.471 x 0.661x0.1x101.91.323112008095550
12402518.237 x 2.900.50.43.42.9626.971 x 0.661x0.1x1021.43314009387200
13002520.561 x 2.550.50.43.42.9629.271 x 0.661x0.1x102.11.4836160010819000
1400352361 x 2.900.50.43.42.9631.760 x 0.851x0.1x152.21.56392000131112000
1500352661 x 3.200.50.43.42.9634.760 x 0.851x0.1x152.31.64422500147115000
16303530.261 x 3.650.50.43.42.9638.960 x 0.851x0.1x152.41.72463000165418900

Standards

Design & Material Standards: IEC 60502-2, IEC 60228 Class 2
Mechanical & Environmental Endurance: Abrasion and tear resistant to EN 60229-4.1, Impact rated to AG2 per EN 60364-5.51, UV resistant to ISO 4892-3
Halogen Content: Halogen-free according to IEC 60754
Electrical & Thermal Ratings: Voltage Rating Uo/U (Um): 6/10 (12)kV; Test Voltage: 21kV AC 50Hz (5 min); Conductor Max Temp: +90°C; Short Circuit Limit (5s): +250°C; Min Bending Radius: 15 × OD
Regulatory Compliance: RoHS Directive 2015/65/EU, REACH EC 1907/2006, CE Marked

Frequently Asked Questions

Q: What is the primary difference between NA2XS2Y 6/10kV and higher voltage versions (12/20kV and 18/30kV)?
A: Due to lower electrical stress, the 6/10kV version utilizes a 3.40mm nominal XLPE insulation thickness (compared to 5.50mm on 12/20kV and 8.00mm on 18/30kV), resulting in a significantly more compact outer diameter and lighter unit weight.

Q: How does the standard NA2XS2Y cable differ from NA2XS(F)2Y and NA2XS(FL)2Y variants?
A: NA2XS2Y is the standard design without waterblocking tapes, engineered for dry or well-drained soils and ducted installations. NA2XS(F)2Y adds longitudinal swellable waterblocking tapes, while NA2XS(FL)2Y incorporates both longitudinal swellable tapes and a bonded radial Al/PET moisture barrier.

Q: Why is Medium Density Polyethylene (MDPE) preferred over PVC for the outer jacket?
A: MDPE provides superior mechanical toughness, puncture resistance, and tear strength (EN 60229-4.1), along with lower moisture permeability and long-term UV resistance according to ISO 4892-3, making it suitable for direct underground burial and pulling through ducts.

Q: What commercial payment terms does Huadong Cable accept for international orders?
A: We accept standard international commercial payment terms, primarily Telegraphic Transfer (T/T, with 30% advance deposit and 70% against shipping documents) and 100% Irrevocable Letter of Credit (L/C) at sight.

Huadong Cable Factory

NA2XS2Y 6/10 (12)kV Cable – Why Choose Huadong Cable?

Huadong Cable Group manufactures NA2XS2Y 6/10 (12)kV medium-voltage cables in strict compliance with IEC 60502-2 and IEC 60228 specifications. Utilizing electrical-grade aluminium rod, our high-speed stranding equipment produces compacted circular Class 2 conductors that minimize overall cross-sectional diameter and surface irregularities. In our triple-extrusion catenary continuous vulcanization (CCV) lines, the conductor screen, high-cleanliness XLPE insulation, and bonded insulation screen are co-extruded under pressurized dry nitrogen curing, ensuring void-free interfaces and negligible partial discharge levels well below standard thresholds.

Backed by more than 20 years of precision cable engineering expertise, Huadong Cable Group operates testing facilities accredited under ISO/IEC 17025 and certified to ISO 9001 and CE quality frameworks. Direct factory supply eliminates intermediary agent markups, allowing us to provide competitive factory pricing, 100% routine testing (including high-voltage AC withstand, dielectric loss, and partial discharge verification) documented via Mill Test Certificates (MTC), continuous drum cuts packaged on heavy-duty ISPM 15 heat-treated export wooden reels, and dependable logistics for international electric utilities and EPC contractors worldwide.

Trusted Manufacturer

Based on high-quality products, a good reputation, and excellent service, we sincerely hope to establish mutually beneficial cooperation with domestic and foreign merchants and create a bright future together.

Our Clients

We are professional cable manufacturers. Thanks to the excellent quality of our cables and continuous product innovation, we export them to over 130 countries worldwide and have received numerous praises from our customers.

Philippines crane cable customers
UK power cable customers
Ghana ABC cable customers
Côte d'Ivoire power cable customers
Ethiopia power cable customers

Our Workshop

HuaDong Cable Group was established in 1999 and covers an area of ​​66,000 square meters, located in the Xiuwu Industrial Zone of Jiaozuo City, China. We have 20 advanced production lines and 25 testing machines, with an annual production capacity of over 15 million kilometers.

Our Workshop

Why choose Huadong cable?

As a leading global cable manufacturer, Huadong Cable delivers high-performance wire and cable solutions engineered to strict international standards. Trusted in over 130 countries, we combine factory-direct advantages with uncompromising quality to power your critical projects worldwide.

AboutHuaDong

Established in 1999, Huadong Cable Group is a national high-tech enterprise and an integrated manufacturer specializing in advanced cable R&D, production, and global trade. Deeply integrated into global infrastructure and the Belt and Road Initiative, Huadong Cable Group exports to over 130 countries and regions worldwide, including Europe, South America, North America, the Middle East, Africa, Asia, and Oceania.

Technology HuaDong

Huadong Cable Group places technology and continuous R&D at the core of our operations. Supported by a robust team of 60 senior R&D specialists and experienced engineers, we hold over 100 national patents and utility models. This strong technical foundation ensures rigorous quality control, exceptional product durability, and tailored engineering support for every client.

Main products

Our comprehensive product includes high-quality power cables, aerial insulated cables (ABC cables), marine cables, flame-retardant & fire-resistant cables, and low-smoke halogen-free (LSZH) cables. We also specialize in rubber cables, high-temperature resistant cables, instrument & control cables, solar/photovoltaic cables, and customized wiring solutions for diverse industrial applications.

ISO, SGS, BV certification; technical patents and product certification

Certification ISO
Certification SGS
Certification TUV
Certification CCC
Certification CE
Certification PCCC
Certification CNAS
Certification UL

TEAMS AND CLIENTS

130+

Export countries

100+

Technical patents

3000 millions+

Annual production

400+

Employees

HuaDong Cable Parties - Foxconn
HuaDong Cable Parties - Keppel Corporation
HuaDong Cable Parties - NNPC
HuaDong Cable Parties  - WBHO
HuaDong Cable Parties - AboitizPower
HuaDong Cable Parties
HuaDong Cable Parties - HELUKABEL
HuaDong Cable Parties - Inalum

    LEAVE A MESSAGE

    Are you interested in our products? Leave your message below and we'll get back to you within six hours.

      Email: sales@hdcablefactory.com

      whatapp-icon
      email-icon